Versatility Across
Every Suite with
MEDRAD® Stellant FLEX
Versatility Across Every Suite with MEDRAD® Stellant FLEX
MEDRAD Stellant FLEX POWERED BY CORTENIC™ CONNECTIVITY
Deliver Quality Patient Care with the MEDRAD Stellant FLEX
The MEDRAD Stellant FLEX, powered by Cortenic Connectivity, is a single-patient, dual syringe injection system with adaptable workflows. Stellant FLEX helps you meet your financial, clinical and organizational goals so that you can continue to deliver quality patient care while maintaining healthy business operations.
Patient-Focused
Care
Operational and
Workflow Versatility
Syringe Cost
Savings
Expanded Clinical
Capabilities
Designed for Operational Flexibility
An easy-to-use injector that adapts to your department’s operational needs across a variety of CT suite workflows, so you can stay focused on patient care.
Intuitive Operation
Easy-to-use interface and intuitive operation drive staff satisfaction and standardization practices.
Operational Versatility and Flexibility
Broad contrast and OEM scanner compatibility provide workflow flexibility, while automated documentation and interoperability may reduce errors and drive efficiency.
Total Lifecycle Value
Smaller syringe design helps reduce costs and environmental impact while our expert service and clinical partnership enable sustained operational and clinical excellence.
Optimized Technology and Performance
Technology built on proven MEDRAD Stellant reliability and backed by
expert clinical and technical services.
Syringe Safety Features
Patented beacon technology and MEDRAD FluiDots provide clear indication of the presence of fluid in the syringe.
DualFlow Technology
DualFlow injects contrast and saline simultaneously for uniform attenuation, fewer artifacts and clearer right coronary and ventricular imaging.¹
Confidence in Quality
US-manufactured syringes with rigorous quality control and validated biocompatibility.
Connectivity Enabled Efficiency
Cortenic Connectivity unlocks access to advanced features, which can help drive workflow efficiency, optimize performance and deliver data for smarter insights.*
*May require additional software purchase
Optimize Contrast with the Imaging Bulk Package Transfer Set
Streamline preparation and optimize in-suite operations with MEDRAD Stellant FLEX and the Imaging Bulk Package
Transfer Set.
Choose Your Contrast
The transfer set is FDA-cleared for use with three iodinated contrast agents in approved imaging bulk packages (IBP).
Improve Workflow Efficiency
Reduces preparation steps for patient injection and may reduce contrast waste vs. single-dose vials.2
Consider Joint Commission Standards
Bayer specialists understand Joint Commission expectations and industry best practices, and will support you through seamless implementation and everyday use of our products.
Contrast-Enhanced Mammography (CEM)
The first and only CT injection system currently 510(k) cleared for use with CEM.
- Accurate contrast dose administration for better visualization of abnormalities in the breast tissue that may not be visible with conventional mammography3
- Consistent contrast delivery for enhanced visualization of breast lesions3
- Small footprint and flexible movement allow for various room configurations*
*Maintain a 4.9ft (1.5m) safe distance between the patient and non-patient devices. Install the workstation (non-patient device) a minimum of 4.9ft (1.5m) from the injector head.
Connectivity for Seamless Workflow Integration
Powered by Cortenic Connectivity, MEDRAD Stellant FLEX is a comprehensive solution to help drive performance across your connected suite, with integrated software, services, education and data.
Specifications
Click below to find the information you need on the MEDRAD Stellant FLEX CT Injection System.
| Description | Height | Width | Depth | Weight |
| Dual Injector Head | 14.5" (36.8 cm) | 12.1" (30.7 cm) | 6.0" (15.2 cm) | 16.8 lbs (7.6 kg) (without syringe) |
| Base Unit | 11.3" (28.6 cm) | 11.0" (27.9 cm) | 9.0" (22.9 cm) | 13.6 lb (6.2 kg) |
| Certegra® Workstation 3.0 (CWS) | 10.2"-10.8" (25.9 cm - 27.3 cm) | 15.1" (38.4 cm) | 6.8"-7.9" (17.3 cm - 20.2 cm) | 15.8 lb (7.2 kg) |
| Flow Rate (Range and Increments) | 0.1 - 10mL/sec in 0.1mL increments | |
| Volume (Range and Increments) | 1 mL to Syringe Capacity in 1-mL Increments | |
| Programmable Pressure Limit | 150 mL and 200 mL Syringe: Choice of 50/345, 100/689, 150/1034, 200/1379, 225/1551, 250/1724, 300/2068, 325/2241 | |
| Scan Reminders | 0 – 300 Seconds (5 minutes) in 1-Second Increments | |
| Pause | 1 – 900 Seconds (15 minutes) in 1-Second Increments | |
| Hold | Maximum HOLD Time is 20 Minutes | |
| Syringes (Volume Capacity) | 150 mL or 200 mL Sterile Disposable Syringe | |
| Maximum Number of Phases | 6 | |
| Barcore Reader | 2D Barcore Reader | |
| Mobile Mount Kit | Simple, secure 2-point mounting system with secure mount for the workstation control room | |
| Remote Connectivity | Foundational connectivity of out connected injectors including critical cybersecurity patches | |
| Remote Diagnostics* | Remote Technical Support | |
| Automated Documentation* | Point of Care Interface (includes Modality Worklist Integration) PACS Interface Speech Recognition Interface RIS Interface Barcore Reader | |
| Contrast Optimization* | P3T Bundle (Abdomen, Cardiac and Pulmonary Angiography) | |
| Scanner Connectivity* | ISI2 Imaging System Interface Connect.CT† | |
| Analytics and Monitoring* | //Workflow Solutions Insights Radimetrics | |
*May require additional software purchase
†Vendor Specific, currently sold as Philips SyncRight
Resources
Check out our helpful resources below to learn more.
Explore Stellant FLEX in our brochure
Download the Stellant FLEX CEM brochure
Review the Stellant FLEX Consumables brochure
View the MEDRAD Injection Systems Syringe brochure
References:
- Kerl JM, Ravenel JG, Nguyen SA, et al. Right heart: split-bolus injection of diluted contrast medium for visualization at coronary CT angiography. Radiology.
2008;247:356-364. - Gadavist IBP [package insert]. Whippany, NJ: Bayer HealthCare Pharmaceuticals Inc; 2025.
- James JJ, Tennant SL, Contrast-enhanced spectral mammography (CESM), Clinical Radiology (2018), https://doi.org/10.1016/j.crad.2018.05.005.